Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 223
Filtrar
1.
Chinese Journal of Trauma ; (12): 214-222, 2023.
Artículo en Chino | WPRIM | ID: wpr-992590

RESUMEN

Hip fracture is considered as the most severe osteoporotic fracture characterized by high disability and mortality in the elderly. Improved surgical techniques and multidisciplinary team play an active role in alleviating prognosis, which places higher demands on perioperative nursing. Dysfunction, complications, and secondary impact of anaesthesia and surgery add more difficulties to clinical nursing. Besides, there still lack clinical practices in perioperative nursing for elderly patients with hip fracture in China. In this context, led by the Orthopedic Nursing Committee of Chinese Nursing Association, the Expert consensus on clinical practice in perioperative nursing for elderly patients with hip fracture ( version 2023) is developed based on the evidence-based medicine. This consensus provides 11 recommendations on elderly patients with hip fracture from aspects of perioperative health education, condition monitoring and inspection, complication risk assessment and prevention, and rehabilitation, in order to provide guiding advices for clinical practice, improve the quality of nursing and ameliorate the prognosis of elderly patients with hip fracture.

2.
Acta Pharmaceutica Sinica ; (12): 2785-2793, 2023.
Artículo en Chino | WPRIM | ID: wpr-999008

RESUMEN

The clinical tumor therapy was greatly challenged due to the complex characteristics of tumor microenvironment, however, which also provide arena for novel therapeutic strategies. In this study, poly(2-ethyl-2-oxazoline)-poly(lactic acid)-SS-poly(β-amino ester (PEOz-PLA-SS-PBAE) triblock copolymers with pH and GSH double response were synthesized, polymer micelles were prepared by thin film hydration method for loading of silybin to improve its antitumor activity. The critical micelle concentration was determined by pyrene fluorescence method as 1.8 μg·mL-1. The particle size was 155.30 ± 1.80 nm as determined by dynamic light scattering, with polydispersity index of 0.168 ± 0.004. The drug loading and entrapment efficiency of the micelles were determined by HPLC as (5.48 ± 0.04)% and (68.52 ± 0.48)%, respectively. The in vitro drug release profiles showed that the micelles have low pH sensitivity and high GSH responsiveness, and exhibited sustained release profiles. The good biocompatibility of the material was proved by measuring the hemolysis rate and cytotoxicity of the blank micelle. The cytotoxicity and apoptosis rate of tumor cells showed that the drug loaded PEOz-PLA-SS-PBAE micelles had significant inhibitory effect and apoptosis-inducing effect on MDA-MB-231 cells. The results of wounding healing assay and Transwell invasion test showed that the drug loaded PEOz-PLA-SS-PBAE micelles could significantly inhibit the metastasis of MDA-MB-231 cells. The PEOz-PLA-SS-PBAE drug-loaded micelles prepared in this study have good inhibitory effect on tumor growth and anti-tumor metastasis in vitro, which lays the foundation for the further application of silybin.

3.
Journal of Peking University(Health Sciences) ; (6): 174-180, 2023.
Artículo en Chino | WPRIM | ID: wpr-971292

RESUMEN

OBJECTIVE@#To explore an efficient and automatic method for determining the anatomical landmarks of three-dimensional(3D) mandibular data, and to preliminarily evaluate the performance of the method.@*METHODS@#The CT data of 40 patients with normal craniofacial morphology were collected (among them, 30 cases were used to establish the 3D mandibular average model, and 10 cases were used as test datasets to validate the performance of this method in determining the mandibular landmarks), and the 3D mandibular data were reconstructed in Mimics software. Among the 40 cases of mandibular data after the 3D reconstruction, 30 cases that were more similar to the mean value of Chinese mandibular features were selected, and the size of the mandibular data of 30 cases was normalized based on the Procrustes analysis algorithm in MATLAB software. Then, in the Geomagic Wrap software, the 3D mandibular average shape model of the above 30 mandibular data was constructed. Through symmetry processing, curvature sampling, index marking and other processing procedures, a 3D mandible structured template with 18 996 semi-landmarks and 19 indexed mandibular anatomical landmarks were constructed. The open source non-rigid registration algorithm program Meshmonk was used to match the 3D mandible template constructed above with the tested patient's 3D mandible data through non-rigid deformation, and 19 anatomical landmark positions of the patient's 3D mandible data were obtained. The accuracy of the research method was evaluated by comparing the distance error of the landmarks manually marked by stomatological experts with the landmarks marked by the method of this research.@*RESULTS@#The method of this study was applied to the data of 10 patients with normal mandibular morphology. The average distance error of 19 landmarks was 1.42 mm, of which the minimum errors were the apex of the coracoid process [right: (1.01±0.44) mm; left: (0.56±0.14) mm] and maximum errors were the anterior edge of the lowest point of anterior ramus [right: (2.52±0.95) mm; left: (2.57±1.10) mm], the average distance error of the midline landmarks was (1.15±0.60) mm, and the average distance error of the bilateral landmarks was (1.51±0.67) mm.@*CONCLUSION@#The automatic determination method of 3D mandibular anatomical landmarks based on 3D mandibular average shape model and non-rigid registration algorithm established in this study can effectively improve the efficiency of automatic labeling of 3D mandibular data features. The automatic determination of anatomical landmarks can basically meet the needs of oral clinical applications, and the labeling effect of deformed mandible data needs to be further tested.


Asunto(s)
Humanos , Imagenología Tridimensional/métodos , Mandíbula/diagnóstico por imagen , Programas Informáticos , Algoritmos , Puntos Anatómicos de Referencia/anatomía & histología
4.
International Journal of Biomedical Engineering ; (6): 30-35, 2023.
Artículo en Chino | WPRIM | ID: wpr-989312

RESUMEN

Objective:To design a motor impairment rehabilitation monitoring aid for the assessment of motor impairment in patients who do not have or have difficulty walking independently.Methods:An assistive device vehicle was designed, equipped with an accelerometer and a six-dimensional force sensor. The normal walking (NW) group and abnormal walking group were set up, in which the abnormal walking group included moderate abnormal walking (MA) group, moderate abnormal walking with the aid of the assistive vehicle (MA-V) group, severe abnormal walking (SA) group, and severe abnormal walking with the aid of the assistive vehicle (SA-V) group. In the MA-V group, the range of knee movement was adjusted from 0 to 30°, and in the SA group, the knee joint was completely unbending. The gait cycles, peak and mean acceleration values of the right and left legs were evaluated by accelerometers, and changes in the upper limb forces were assessed by six-dimensional force transducers.Results:For the moderate impairment group, the difference in gait cycle between the MA and MA-V groups was not statistically significant ( P>0.05), and the gait cycle in the MA-V group was slightly greater than that in the MA group. For the severe injury group, the gait cycle of the SA-V group was lower than that of the SA group, and the difference was statistically significant ( P<0.01). For all abnormal groups, the mean and peak acceleration of the left leg were greater than that of the right leg, and the difference between the peak acceleration of the left leg and that of the right leg was statistically significant ( P<0.05). In the abnormal walking pattern, the mean (absolute) value of the left hand force was greater than that of the right hand, especially in the Z-axis. The standard deviations of the combined forces on the left side for the NW, MA-V, and SA-V groups were 2.759, 8.297, and 13.118 N, respectively. The SA-V group had the highest dispersion in the force scatter plot, while the NW group had a better concentration. Conclusions:An assistive vehicle equipped with an accelerometer and a six-dimensional force sensor was designed to help physicians in the assessment and rehabilitation of motor disorders.

5.
Journal of Peking University(Health Sciences) ; (6): 343-350, 2023.
Artículo en Chino | WPRIM | ID: wpr-986859

RESUMEN

OBJECTIVE@#To quantitatively evaluate the trueness of five chairside three-dimensional facial scanning techniques, and to provide reference for the application of oral clinical diagnosis and treatment.@*METHODS@#The three-dimensional facial data of the subjects were collected by the traditional professional three-dimensional facial scanner Face Scan, which was used as the reference data of this study. Four kinds of portable three-dimensional facial scanners (including Space Spider, LEO, EVA and DS-FScan) and iPhone Ⅹ mobile phone (Bellus3D facial scanning APP) were used to collect three-dimensional facial data from the subjects. In Geomagic Studio 2013 software, through data registration, deviation analysis and other functions, the overall three-dimensional deviation and facial partition three-dimensional deviation of the above five chairside three-dimensional facial scanning technologies were calculated, and their trueness performance evaluated. Scanning time was recorded during the scanning process, and the subject's comfort was scored by visual analogue scale(VAS). The scanning efficiency and patient acceptance of the five three-dimensional facial scanning techniques were evaluated.@*RESULTS@#DS-FScan had the smallest mean overall and mean partition three-dimensional deviation between the test data and the reference data, which were 0.334 mm and 0.329 mm, respectively. The iPhone Ⅹ mobile phone had the largest mean overall and mean partition three-dimensional deviation between the test data and the reference data, which were 0.483 mm and 0.497 mm, respectively. The detailed features of the three-dimensional facial data obtained by Space Spider were the best. The iPhone Ⅹ mobile phone had the highest scanning efficiency and the highest acceptance by the subject. The average scanning time of the iPhone Ⅹ mobile phone was 14 s, and the VAS score of the subjects' scanning comfort was 9 points.@*CONCLUSION@#Among the five chairside three-dimensional face scanning technologies, the trueness of the scan data of the four portable devices had no significant difference, and they were all better than the iPhone Ⅹ mobile phone scan. The subject with the iPhone Ⅹ scanning technology had the best expe-rience.


Asunto(s)
Imagenología Tridimensional , Programas Informáticos , Modelos Dentales
6.
Chinese Journal of Stomatology ; (12): 554-560, 2023.
Artículo en Chino | WPRIM | ID: wpr-986110

RESUMEN

Objective: To explore an automatic landmarking method for anatomical landmarks in the three-dimensional (3D) data of the maxillary complex and preliminarily evaluate its reproducibility and accuracy. Methods: From June 2021 to December 2022, spiral CT data of 31 patients with relatively normal craniofacial morphology were selected from those who visited the Department of Oral and Maxillofacial Surgery, Peking University School and Hospital of Stomatology. The sample included 15 males and 16 females, with the age of (33.3±8.3) years. The maxillary complex was reconstructed in 3D using Mimics software, and the resulting 3D data of the maxillary complex was mesh-refined using Geomagic software. Two attending physicians and one associate chief physician manually landmarked the 31 maxillary complex datasets, determining 24 anatomical landmarks. The average values of the three expert landmarking results were used as the expert-defined landmarks. One case that conformed to the average 3D morphological characteristics of healthy individuals' craniofacial bones was selected as the template data, while the remaining 30 cases were used as target data. The open-source MeshMonk program (a non-rigid registration algorithm) was used to perform an initial alignment of the template and target data based on 4 landmarks (nasion, left and right zygomatic arch prominence, and anterior nasal spine). The template data was then deformed to the shape of the target data using a non-rigid registration algorithm, resulting in the deformed template data. Based on the unchanged index property of homonymous landmarks before and after deformation of the template data, the coordinates of each landmark in the deformed template data were automatically retrieved as the automatic landmarking coordinates of the homonymous landmarks in the target data, thus completing the automatic landmarking process. The automatic landmarking process for the 30 target data was repeated three times. The root-mean-square distance (RMSD) of the dense corresponding point pairs (approximately 25 000 pairs) between the deformed template data and the target data was calculated as the deformation error of the non-rigid registration algorithm, and the intra-class correlation coefficient (ICC) of the deformation error in the three repetitions was analyzed. The linear distances between the automatic landmarking results and the expert-defined landmarks for the 24 anatomical landmarks were calculated as the automatic landmarking errors, and the ICC values of the 3D coordinates in the three automatic landmarking repetitions were analyzed. Results: The average three-dimensional deviation (RMSD) between the deformed template data and the corresponding target data for the 30 cases was (0.70±0.09) mm, with an ICC value of 1.00 for the deformation error in the three repetitions of the non-rigid registration algorithm. The average automatic landmarking error for the 24 anatomical landmarks was (1.86±0.30) mm, with the smallest error at the anterior nasal spine (0.65±0.24) mm and the largest error at the left oribital (3.27±2.28) mm. The ICC values for the 3D coordinates in the three automatic landmarking repetitions were all 1.00. Conclusions: This study established an automatic landmarking method for three-dimensional data of the maxillary complex based on a non-rigid registration algorithm. The accuracy and repeatability of this method for landmarking normal maxillary complex 3D data were relatively good.


Asunto(s)
Masculino , Femenino , Humanos , Adulto , Imagenología Tridimensional/métodos , Reproducibilidad de los Resultados , Algoritmos , Programas Informáticos , Tomografía Computarizada Espiral , Puntos Anatómicos de Referencia/anatomía & histología
7.
Chinese Journal of Stomatology ; (12): 435-441, 2023.
Artículo en Chino | WPRIM | ID: wpr-986091

RESUMEN

Objective: To explore a method for digitally designing and fabricating a sequential tooth-sectioning guide that can assist in the extraction of mandibular horizontal impacted third molars, preliminarily evaluate its feasibility and provide a reference for clinical application. Methods: Twenty patients with mandibular low level impacted third molars who visited the Department of General Dentistry, Peking University School and Hospital of Stomatology from March 2021 to January 2022 were selected. Cone-beam CT showed direct contact between the roots and mandibular canal, and full range impressions of the patients' intraoral teeth were taken and optical scans of the dental model were performed. The patients' cone-beam CT data and optical scan data were reconstructed in three dimensions, anatomical structure extraction, registration fusion, and the design of the structure of the guide (including crown-sectioning guide and root-sectioning guide) by Mimics 24.0, Geomagic Wrap 2021, and Magics 21.0 software, and then the titanium guide was three dimension printed, and the guide was tried on the dental model. After confirmation, the guide was used to assist the dentist in the operation. We observed whether the guide was in place, the number of tooth splitting, the matching of tooth splitting with the preoperative design, the operation time, and whether there were any complications. Results: In this study, 20 sectioning guides were successfully printed, all of them were well fitted in the patients' mouth, the average number of section was 3.4 times, the tooth parts was better matched with the preoperative design, and the average operative time of the guides was (29.2±9.8) minutes without complications such as perforation of the bone cortex. Conclusions: The use of sequential sectioning guides to assist in the extraction of mandibular impacted third molars was initially validated to accurately replicate the preoperative sectioning design, and is expected to provide a digital solution to improve surgical precision and ensure safety. Further studies with larger sample sizes are needed to evaluate its accuracy and safety.

8.
Chinese Journal of Stomatology ; (12): 414-421, 2023.
Artículo en Chino | WPRIM | ID: wpr-986088

RESUMEN

Objective: To provide a new solution for the digital design of nasal prostheses, this study explores the three-dimensional (3D) facial morphology completion method for external nasal defects based on the non-rigid registration process of 3D face template. Methods: A total of 20 male patients with tooth defect and dentition defect who visited the Department of Prosthodontics, Peking University School and Hospital of Stomatology from June to December 2022 were selected, age 18-45 years old. The original 3D facial data of patients were collected, and the 3D facial data of the external nose defect was constructed in Geomagic Wrap 2021 software. Using the structured 3D face template data constructed in the previous research of the research group, the 3D face template was deformed and registered to the 3D facial data of external nose defect (based on the morphology of non-defective area) by non-rigid registration algorithm (MeshMonk program), and the personalized deformed data of the 3D face template was obtained, as the complemented facial 3D data. Based on the defect boundary of the 3D facial data of the external nose defect, the complemented external nose 3D data can be cut out from the complemented facial 3D data. Then the nasofacial angle and nasolabial angle of the complemented facial 3D data and the original 3D facial data was compared and analyzed, the ratio between the nose length and mid-face height, nose width and medial canthal distance of the complemented facial 3D data was measured, the edge fit between the edge curve of the complemented external nose 3D data and the defect edge curve of the 3D facial data of external nose defect was evaluated, and the morphological difference of the nose between the complemented external nose 3D data and the original 3D facial data was analyzed. Results: There was no significant statistically difference (t=-0.23, P=0.823; Z=-1.72, P=0.086) in the nasofacial angle (28.2°±2.9°, 28.4°±3.5° respectively) and nasolabial angle [95.4°(19.2°), 99.9°(9.5°) respectively] between the 20 original 3D facial data and the complemented facial 3D data. The value of the ratio of nose length to mid-face height in the complemented facial 3D data was 0.63±0.03, and the value of the ratio of nose width to medial canthal distance was 1.07±0.08. The curve deviation (root mean square value) between the edge curve of the complemented external nose 3D data and the defect edge curve of the 3D facial data of external nose defect was (0.37±0.09) mm, the maximum deviation was (1.14±0.32) mm, and the proportion of the curve deviation value within±1 mm was (97±3)%. The distance of corresponding nose landmarks between the complemented facial 3D data and the original 3D facial data were respectively, Nasion: [1.52(1.92)] mm; Pronasale: (3.27±1.21) mm; Subnasale: (1.99±1.09) mm; Right Alare: (2.64±1.34) mm; Left Alare: (2.42± 1.38) mm. Conclusions: The method of 3D facial morphology completion of external nose defect proposed in this study has good feasibility. The constructed complemented external nose 3D data has good facial coordination and edge fit, and the morphology is close to the nose morphology of the original 3D facial data.

9.
Chinese Journal of Pediatrics ; (12): 235-239, 2023.
Artículo en Chino | WPRIM | ID: wpr-970273

RESUMEN

Objective: To explore the application value of percutaneous peripheral interventional therapy in pulmonary atresia with intact ventricular septal (PA-IVS). Methods: Retrospective case summary. The data was collected from 25 children who were hospitalized at the Children's Hospital,Zhejiang University School of Medicine from August 2019 to August 2022, had been diagnosed with PA-IVS by echocardiography, and underwent interventional treatment. The sex, age, weight, operation time, radiation exposure time, and radiation dose of the patients were collected. The patients were divided into the arterial duct stenting group and the non-stenting group. Preoperative tricuspid annular diameters and Z scores, right ventricular length diameters, and right ventricular/left ventricular length-diameter ratios were compared by paired t-tests. Right ventricular systolic pressure difference, oxygen saturation, lactic acid before and after the surgery were compared for 24 children who received percutaneous balloon pulmonary valvuloplasty. Right ventricular improvement in 25 children after operation was analyzed. The correlation between postoperative oxygen saturation and postoperative right ventricular systolic blood pressure difference, the degree of pulmonary valve opening and the Z value of tricuspid valve ring in the non-stenting group were analyzed. Results: A total of 25 patients with PA-IVS were enrolled in the study, of whom 19 were males and 6 females, with an age at surgery of 12 (6, 28) days and a weight of (3.7±0.5) kg. One of them underwent only stenting of the arterial duct; 20 children underwent only percutaneous pulmonary valve perforation and balloon angioplasty; 4 children underwent both procedures. The Z-value of the tricuspid ring was -1.5±1.2 in the group with arterial duct stenting, and -0.1±0.4 in the group without stenting (t=2.77, P=0.010). The tricuspid regurgitant flow rate 1 month after surgery was significantly lower than the preoperative ((3.4±0.6) vs. (4.8±0.9) m/s, t=6.62,P<0.001). In the 24 children with percutaneous pulmonary valve perforation and balloon angioplasty, the preoperative right ventricular systolic blood pressure was (110±32) mmHg, and the postoperative systolic blood pressure was (52±19) mmHg (1 mmHg=0.133 kPa) (F=59.55, P<0.001). The factors that may affect postoperative oxygen saturation in 20 cases of non-stenting group were analyzed. The results suggested that the pre and post-operative right ventricular systolic blood pressure differences (r=-0.11, P=0.649), and the pulmonary valve orifice opening (r=-0.31, P=0.201) and tricuspid annulus Z value (r=-0.18, P=0.452) at 1 month after the operation were not significantly correlated with the postoperative oxygen saturation. Conclusions: Interventional therapy can be used as the first choice for one-stage operation of PA-IVS. Percutaneous pulmonary valve perforation and balloon angioplasty are more suitable for children with well-developed right ventricles, tricuspid annulus, and pulmonary arteries. While the smaller the tricuspid annulus, the more dependent it is on the ductus arteriosus and thus patients are more suitable for arterial duct stenting.


Asunto(s)
Niño , Femenino , Masculino , Humanos , Atresia Pulmonar/cirugía , Estudios de Seguimiento , Estudios Retrospectivos , Cardiopatías Congénitas/cirugía
10.
Chinese Journal of Hematology ; (12): 55-61, 2023.
Artículo en Chino | WPRIM | ID: wpr-969708

RESUMEN

Objective: To analyze the clinical characteristics and prognosis of primary and secondary pancreatic diffuse large B-cell lymphoma (DLBCL) . Methods: Clinical data of patients with pancreatic DLBCL admitted at Shanghai Rui Jin Hospital affiliated with Shanghai Jiao Tong University School of Medicine from April 2003 to June 2020 were analyzed. Gene mutation profiles were evaluated by targeted sequencing (55 lymphoma-related genes). Univariate and multivariate Cox regression models were used to evaluate the prognostic factors of overall survival (OS) and progression-free survival (PFS) . Results: Overall, 80 patients were included; 12 patients had primary pancreatic DLBCL (PPDLBCL), and 68 patients had secondary pancreatic DLBCL (SPDLBCL). Compared with those with PPDLBCL, patients with SPDLBCL had a higher number of affected extranodal sites (P<0.001) and had higher IPI scores (P=0.013). There was no significant difference in the OS (P=0.120) and PFS (P=0.067) between the two groups. Multivariate analysis indicated that IPI intermediate-high/high risk (P=0.025) and double expressor (DE) (P=0.017) were independent adverse prognostic factors of OS in patients with pancreatic DLBCL. IPI intermediate-high/high risk (P=0.021) was an independent adverse prognostic factor of PFS in patients with pancreatic DLBCL. Targeted sequencing of 29 patients showed that the mutation frequency of PIM1, SGK1, BTG2, FAS, MYC, and MYD88 in patients with pancreatic DLBCL were all >20%. PIM1 (P=0.006 for OS, P=0.032 for PFS) and MYD88 (P=0.001 for OS, P=0.017 for PFS) mutations were associated with poor OS and PFS in patients with SPDLBCL. Conclusion: There was no significant difference in the OS and PFS between patients with PPDLBCL and those with SPDLBCL. IPI intermediate-high/high risk and DE were adverse prognostic factors of pancreatic DLBCL. PIM1, SGK1, BTG2, FAS, MYC, and MYD88 were common mutations in pancreatic DLBCL. PIM1 and MYD88 mutations indicated worse prognosis.


Asunto(s)
Humanos , Factor 88 de Diferenciación Mieloide , Supervivencia sin Enfermedad , Estudios Retrospectivos , China/epidemiología , Pronóstico , Linfoma de Células B Grandes Difuso/tratamiento farmacológico , Protocolos de Quimioterapia Combinada Antineoplásica , Páncreas/patología , Proteínas Inmediatas-Precoces/uso terapéutico , Proteínas Supresoras de Tumor
11.
Chinese Journal of Biologicals ; (12): 163-165+171, 2023.
Artículo en Chino | WPRIM | ID: wpr-965862

RESUMEN

@#Objective To investigate the effect of silencing E6-associated protein(E6AP)on the level of p53 protein in human papilloma virus(HPV)negative cervical cancer cells(C33A cells).Methods The siRNA sequence silencing E6AP(siE6AP)and silencing control disordered siRNA sequence(siControl)were transfected into C33A cells with the mediation of LipofectamineTM2000 transfection reagent respectively.The silencing effect of siRNA on E6AP and the expression of p53and cleaved-caspase-3 proteins were detected by Western blot.Results The levels of E6AP protein in C33A cells of siE6AP group were significantly lower(t =-4.597,P<0.05),while the levels of p53 and cleaved-caspase-3 proteins were significantly higher than those of siControl group(t = 4.533 and 7.099 respectively,each P<0.05).Conclusion Silencing of E6AP significantly increased the expression of p53 protein in C33A cells,indicating that silencing of E6AP may restore the activity and function of p53 protein in C33A cells.

12.
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery ; (12): 154-158, 2023.
Artículo en Chino | WPRIM | ID: wpr-953773

RESUMEN

@#Obesity, sleep disorders, psychological stress, sedentary are modifiable cardiovascular risk factors. There is growing evidence that these risk factors may accelerate the chronic inflammatory process of atherosclerosis and lead to myocardial infarction. Studies on the role of immune cells and their related immune mechanisms in atherosclerosis have shown that the above modifiable risk factors can affect the hematopoiesis of the bone marrow system, affect the production of immune cells and phenotypes, and then affect the progress of atherosclerosis. This review will focus on the effects of modifiable cardiovascular risk factors on the progression of atherosclerosis through the role of the innate immune system.

13.
Acta Academiae Medicinae Sinicae ; (6): 303-310, 2023.
Artículo en Chino | WPRIM | ID: wpr-981268

RESUMEN

The research on androgen receptor (AR) in breast cancer is advancing.Although the prognostic value of AR in triple negative breast cancer (TNBC) is controversial,a variety of studies have demonstrated that the lack of AR expression exacerbates disease progression.Moreover,the TNBC subtype of AR(-) is more aggressive than that of AR(+) due to the lack of prognostic biomarkers and therapeutic targets.With the discovery and deepening research of novel therapeutic targets such as phosphatidylinositol 3-kinase/protein kinase B/mammalian target of rapamycin and S-phase kinase-associated protein 2 signaling pathways,as well as the emerging of immunotherapies,the treatment options for TNBC are increasing.Regarding the role of AR in TNBC,the studies about the tumor biology of AR(-)TNBC and novel biomarkers for improved management of the disease remain insufficient.In this review,we summarize the research progress of AR in TNBC,put forward avenues for future research on TNBC,and propose potential biomarkers and therapeutic strategies that warrant investigation.


Asunto(s)
Humanos , Neoplasias de la Mama Triple Negativas/patología , Receptores Androgénicos/metabolismo , Pronóstico , Biomarcadores , Transducción de Señal
14.
Int. j. morphol ; 40(1): 98-101, feb. 2022. ilus, tab, graf
Artículo en Inglés | LILACS | ID: biblio-1385599

RESUMEN

SUMMARY: To investigate the correlation between the anatomical morphology of palatal rugae and sex. The study sample consisted of 120 students studying from Shanxi Medical University, of which 60 were females and 60 were males. The digital model of the palatal rugae was obtained by the 3 Shape TRIOS intraoral scanner. And the shapes of palatal rugae were recorded. Association between palatal rugae shape and sex were tested using Chi-square analysis. And logistic regression analysis (LRA) was carried out to calculate the accuracy of gender prediction using rugae shapes. There was a statistically significant difference between males and females in terms of the distribution of wavy and circular palate rugae. The use of logistic regression analysis obtained a sex predictive value of 65 % when all the rugae shapes were analyzed. Digital images of the palatal rugae morphology contribute to more accurate and convenient for data collection and transformation. It was found that rugae patterns can moderately identify the sex of the specific population when multivariate statistics such as LRA is applied. The palatal rugae morphology can be utilized as an assistant measure for sex identification.


RESUMEN: Investigar la correlación entre la morfología anatómica de las rugas palatinas y el sexo. En la muestra de este estudio se incluyeron 120 estudiantes de la Universidad Médica de Shanxi, (60 mujeres y 60 hombres). El modelo digital de las rugas palatinas se obtuvo mediante escáner intraoral 3 Shape TRIOS, y se registraron las formas de las rugas palatinas. La asociación entre la forma de las rugas palatinas y el sexo se evaluó mediante un análisis de Chi-cuadrado; para calcular la precisión de la predicción de sexo se llevó a cabo un análisis de regresión logística (ARL) Se observó una diferencia estadísticamente significativa entre hombres y mujeres en términos de la distribución de las rugas palatinas onduladas y circulares. El uso de análisis de regresión logística obtuvo un valor predictivo de sexo del 65 % cuando se analizaron todas las formas de las rugas. Las imágenes digitales de la morfología de las rugas palatinas contribuyen a una recopilación de datos más precisa. En este análisis se determinó que los patrones de rugas pueden identificar relativamente el sexo de una población específica, cuando se aplican estadísticas multivariadas como ARL. La morfología de las rugas palatinas se puede utilizar como medida de ayuda para la identificación de sexo.


Asunto(s)
Humanos , Masculino , Femenino , Adolescente , Adulto , Adulto Joven , Caracteres Sexuales , Antropología Forense , Paladar Duro/anatomía & histología , Distribución de Chi-Cuadrado , Valor Predictivo de las Pruebas , Análisis de Regresión , Determinación del Sexo por el Esqueleto
15.
Journal of Southern Medical University ; (12): 1062-1068, 2022.
Artículo en Chino | WPRIM | ID: wpr-941042

RESUMEN

OBJECTIVE@#To investigate the effects of co-expression of sodium iodide symporter (NIS) reporter gene on the proliferation and cytotoxic activity of chimeric antigen receptor (CAR)-T cells in vitro.@*METHODS@#T cells expressing CD19 CAR (CAR-T cells), NIS reporter gene (NIS-T cells), and both (NIS-CAR-T cells) were prepared by lentiviral infection. The transfection rates of NIS and CAR were determined by flow cytometry, and the cell proliferation rate was assessed using CCK-8 assay at 24, 48 and 72 h of routine cell culture. The T cells were co-cultured with Nalm6 tumor cells at the effector-target ratios of 1∶2, 1∶1, 2∶1 and 4∶1 for 24, 48 and 72 h, and the cytotoxicity of CAR-T cells to the tumor cells was evaluated using lactate dehydrogenase (LDH) assay. ELISA was used to detect the release of IFN-γ and TNF-β in the co-culture supernatant, and the function of NIS was detected with iodine uptake test.@*RESULTS@#The CAR transfection rate was 91.91% in CAR-T cells and 99.41% in NIS-CAR-T cells; the NIS transfection rate was 47.83% in NIS-T cells and 50.24% in NIS- CAR-T cells. No significant difference in the proliferation rate was observed between CAR-T and NIS-CAR-T cells cultured for 24, 48 or 72 h (P> 0.05). In the co-cultures with different effector-target ratios, the tumor cell killing rate was significantly higher in CAR-T group than in NIS-CAR-T group at 24 h (P < 0.05), but no significant difference was observed between the two groups at 48 h or 72 h (P>0.05). Higher IFN-γ and TNF-β release levels were detected in both CAR-T and NIS-CAR-T groups than in the control group (P < 0.05). NIS-T cells and NIS-CAR-T cells showed similar capacity of specific iodine uptake (P>0.05), which was significantly higher than that in the control T cells (P < 0.05).@*CONCLUSION@#The co-expression of the NIS reporter gene does not affect CAR expression, proliferation or tumor cell-killing ability of CAR-T cells.


Asunto(s)
Antineoplásicos , Línea Celular Tumoral , Proliferación Celular , Yodo , Linfotoxina-alfa , Receptores Quiméricos de Antígenos , Simportadores , Linfocitos T
16.
Chinese Journal of Preventive Medicine ; (12): 541-544, 2022.
Artículo en Chino | WPRIM | ID: wpr-935321

RESUMEN

To analyze a suspected case of Clostridium botulinum food poisoning in Bayingolin Mongolian Autonomous Prefecture, Xinjiang and to help validating the diagnosis and providing technical support for clinical treatment. The basic information and clinical manifestations of food poisoning cases were investigated by using the epidemiological method of food safety accidents. The botulinum toxin genes in the samples were detected by real-time PCR and inoculation of KM mouse. The enriched bacteria were further purified and validated. PFGE and cluster analysis were performed on five isolates. Clostridium botulinum type A was detected in two homemade fermented bean samples and stool lavage fluid samples of three patients from enriched samples by toxin test and real-time PCR, and were further validated after isolation of Clostridium botulinum. PFGE showed 100% homology among five isolates. Five isolates of bacteria isolated from the stool lavage fluid of three patients and two homemade fermented bean curd were identified as the same source through PFGE. The cause of this food poisoning cases is food pollution of Clostridium botulinum type A.


Asunto(s)
Animales , Humanos , Ratones , Clostridium botulinum/genética , Heces , Enfermedades Transmitidas por los Alimentos/epidemiología , Gerbillinae
17.
Chinese Journal of Oncology ; (12): 219-227, 2022.
Artículo en Chino | WPRIM | ID: wpr-935204

RESUMEN

Non-small cell lung cancer (NSCLC) is one of the most severe malignant tumors worldwide. Lobectomy and systematic nodal dissection remain the standard treatment for stageⅠNSCLC. Stereotactic body radiotherapy (SBRT) has become the standard treatment for medically inoperable patients. Though the prognosis of stage Ⅰ NSCLC patients is generally good, there are still about 20% of patients with local recurrence and distant metastasis. There is significant heterogeneity in the prognosis and failure phenotype of patients, which cannot be precisely distinguished by the pathological TNM classification system. Identification of the risk factors for the prognosis of patients with stage Ⅰ NSCLC is a key step to realize the treatment from experience to precision. Screening the high-risk patients will facilitate to individually develop the adjuvant therapy strategy after surgery or SBRT and improve the overall curative effect. There are many factors that are significantly related to the prognosis of stage Ⅰ NSCLC including individual factors such as gender, age, and systemic inflammatory biomarkers; treatment-related factors such as the extent of surgical resection of the primary tumor and lymph nodes, the choice of different radiation rays, and different dose fractionation; and tumor-related factors such as imaging information, pathology information; and molecular biology information. This review will analyze the treatment failure phenotype and prognostic factors of stageⅠ NSCLC in various perspectives such as individual-, tumor- and treatment-related factors.


Asunto(s)
Humanos , Carcinoma de Pulmón de Células no Pequeñas/cirugía , Neoplasias Pulmonares/patología , Fenotipo , Pronóstico , Insuficiencia del Tratamiento
18.
China Occupational Medicine ; (6): 439-2022.
Artículo en Chino | WPRIM | ID: wpr-965128

RESUMEN

@#Abstract: Occupational epidemiology aims to explore the effect of occupational hazards on the health of workers and understand , their mechanisms. It plays an important role in occupational health and occupational medicine.Currently occupational , , exposures in the workplace are complex and diverse and multiple factors affect workers´ health at the same time. Therefore it is important to elucidate the pathogenesis of occupational disease caused by occupational hazards and implement early - - intervention. System epidemiology collects data on multi level exposure and multi omics information to conduct network analysis - on the relationship amongrisk factors. and to study the mechanisms of exposures and health outcomes based on multi level data. , , , , Using the study design of system epidemiology occupational environmental lifestyle and social factors are combined as a , system to evaluate the health of workers which can better evaluate the adverse health effects caused by occupational hazards. - , , The studies base on multi omics design will explore the pathogenesis of occupational diseases at the molecular cellular and tissue levels to evaluate the impact of occupational hazards on workers´ health and to explore interventions from multiple - perspectives to reduce the occurrence of occupational or work related diseases.

19.
Chinese Journal of Cardiology ; (12): 137-141, 2022.
Artículo en Chino | WPRIM | ID: wpr-935117

RESUMEN

Objective: To evaluate the safety and efficacy of transcatheter aortic valve implantation (TAVI) with the novel Prizvalve® system in treating severe aortic stenosis. Methods: This is a single-center, prospective, single-arm, observational study. A total of 11 patients with severe aortic stenosis with high risk or inappropriate for conventional surgical aortic valve replacement (SAVR) were included, and TAVI was achieved with the Prizvalve® system between March 2021 and May 2021 in West China Hospital. Transthoracic echocardiography (TTE) was performed immediately after prosthesis implantation to evaluate mean transaortic gradient and maximal transaortic velocity. The device success rate was calculated, which was defined as (1) the device being delivered via the access, deployed, implanted and withdrawn, (2) mean transaortic gradient<20 mmHg (1 mmHg=0.133 kPa) or a maximal transaortic velocity<3 m/s post TAVI, and without severe aortic regurgitation or paravalvular leak post TAVI. TTE was performed at 30 days after the surgery, and all-cause mortality as well as the major cardiovascular adverse events (including acute myocardial infarction, disabling hemorrhagic or ischemic stroke) up to 30 days post TAVI were analyzed. Results: The age of 11 included patients were (78.1±6.3) years, with 8 males. A total of 10 patients were with NYHA functional class Ⅲ or Ⅳ. Devices were delivered via the access, deployed, implanted and withdrawn successfully in all patients. Post-implant mean transaortic gradient was (7.55±4.08) mmHg and maximal transaortic velocity was (1.78±0.44) m/s, and both decreased significantly as compared to baseline levels (both P<0.05). No severe aortic regurgitation or paravalvular leak was observed post TAVI. Device success was achieved in all the 11 patients. No patient died or experienced major cardiovascular adverse events up to 30 days post TAVI. Mean transaortic gradient was (9.45±5.07) mmHg and maximal transaortic velocity was (2.05±0.42) m/s at 30 days post TAVI, which were similar as the values measured immediately post TAVI (both P>0.05). Conclusions: TAVI with the Prizvalve® system is a feasible and relatively safe procedure for patients with severe aortic stenosis and at high risk or inappropriate for SAVR. Further clinical studies could be launched to obtain more clinical experience with Prizvalve® system.


Asunto(s)
Anciano , Anciano de 80 o más Años , Humanos , Masculino , Válvula Aórtica , Estenosis de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas , Estudios Prospectivos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
20.
Journal of Korean Neurosurgical Society ; : 523-530, 2022.
Artículo en Inglés | WPRIM | ID: wpr-938085

RESUMEN

Objective@#: To evaluate the safety and efficacy of an overlapped stenting-assisted coiling technique in treating vertebral artery dissecting aneurysm (VADA) via Low-profile Visualized Intraluminal Support (LVIS) stent-within-Neuroform EZ stent. @*Methods@#: From January 2017 to June 2019, 18 consecutive patients with VADAs (ruptured : unruptured=5 : 13) were treated with the overlapping stents assisted-coiling technique in our center. The overlapping manner was a Neuroform EZ stent being deployed first, followed by LVIS stents placement using the ‘shelf’ technique. The patients’ clinical characteristics, technical feasibility and safety, and immediate and follow-up angiographic results were retrospectively reviewed. @*Results@#: Seventeen (94.4%) procedures were technically successful with an exact deployment of the stents and patent parent or perforator arteries. The immediate angiographies after procedure confirmed Raymond class I, II, and III occlusion of VADAs were in 12 (66.7%), two (11.1%), and four cases (22.2%), respectively. Post-procedural complications developed in one patient (5.6%) with minor brainstem infarctions, which resulted from an in-stent thrombosis during the procedure. Angiographic follow-up at 5.7 months (range 3 to 9 months) demonstrated Raymond class I and II occlusion were in all cases (100%). The modified Rankin Scale scores at 21.3 months (range 15 to 42 months) 0–2 in 17 cases (94.4%) and three in one case (5.6%). @*Conclusion@#: Overlapping stents via LVIS stent-within-Neuroform EZ stent combined with coiling is safe and effective for patients with VADA in the midterm results.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA